mqx: C gas sensors mq2-mq9
Implement a single source file for the following:
* mq2: H2/LPG/CH4/CO/alcohol/smoke/propane/etc
* mq3: Alcohol/benzine/CH4/hexane/LPG/CO
* mq4: CNG (mostly methane)
* mq5: H2/LPG/CH4/CO/alcohol
* mq6: LPG (mostly propane/butane)
* mq7: CO
* mq8: H
* mq9: CO/CH4/LPG
The documentation for these sensors notes that they do not read an exact
gas concentration. Some of the sensors have examples for how to
calibrate with a 'clean air environment' for outputing ppm, but this is
not the case for all mqx sensors. Because of this, the output can be
read as a normalized output (0.0->1.0), raw volts (normalized * aRef),
or a scaled/offset voltage.
Signed-off-by: Noel Eck <noel.eck@intel.com>
This commit is contained in:
@@ -1,5 +1,8 @@
|
||||
set (libname "gas")
|
||||
set (libdescription "Gas sensors")
|
||||
set (module_src ${libname}.cxx mq2.cxx mq3.cxx mq4.cxx mq5.cxx mq6.cxx mq7.cxx mq8.cxx mq9.cxx tp401.cxx)
|
||||
set (module_hpp ${libname}.hpp mq2.hpp mq3.hpp mq4.hpp mq5.hpp mq6.hpp mq7.hpp mq8.hpp mq9.hpp tp401.hpp)
|
||||
upm_module_init()
|
||||
upm_mixed_module_init (NAME gas
|
||||
DESCRIPTION "Gas sensors"
|
||||
C_HDR mqx.h
|
||||
C_SRC mqx.c
|
||||
CPP_HDR gas.hpp mq2.hpp mq3.hpp mq4.hpp mq5.hpp mq6.hpp mq7.hpp mq8.hpp mq9.hpp tp401.hpp
|
||||
CPP_SRC gas.cxx mq2.cxx mq3.cxx mq4.cxx mq5.cxx mq6.cxx mq7.cxx mq8.cxx mq9.cxx tp401.cxx
|
||||
FTI_SRC mqx_fti.c
|
||||
REQUIRES mraa)
|
||||
|
||||
Reference in New Issue