Since UPM uses doxy2swig, there is no need for the swig interface
file autodoc for python.
Also, turned on the doxy2swig --quiet switch which cleans up the build
log a tiny bit.
This removes a redundant chunk of documentation from python modules
(per each function).
Old:
def pH(self, samples=15):
+-> """
| pH(DFRPH self, unsigned int samples=15) -> float
|
| Parameters
| ----------
swig| samples: unsigned int
|
| pH(DFRPH self) -> float
|
| Parameters
| ----------
+-> self: upm::DFRPH *
+-> float pH(unsigned int
| samples=15)
|
| Take a number of samples and return the detected pH value. The default
| number of samples is 15.
|
doxy2swig| Parameters:
| -----------
|
| samples: The number of samples to average over, default 15
|
| The pH value detected
| """
+-> return _pyupm_dfrph.DFRPH_pH(self, samples)
New:
def pH(self, samples=15):
+-> """
| float pH(unsigned int
| samples=15)
|
| Take a number of samples and return the detected pH value. The default
| number of samples is 15.
|
doxy2swig| Parameters:
| -----------
|
| samples: The number of samples to average over, default 15
|
| The pH value detected
+-> """
Signed-off-by: Noel Eck <noel.eck@intel.com>
This module implements support for the Honeywell TB7300 Communicating
Fan Coil Thermostat. It may also support the TB7200, though only the
TB7300 was available for development of this driver.
The TB7200 Series PI thermostats are designed for zoning applications,
and the TB7300 Series PI thermostats are designed for fan coil
control. Both Series are communicating thermostats with models
available in BACnet® MS/TP protocol and can be easily integrated into
a WEBs-AX building automation system based on the NiagaraAX® platform.
TB7200 and TB7300 Series thermostats are compatible with the Honeywell
Occupancy Sensor Cover. Thermostats equipped with an occupancy sensor
cover provide advanced active occupancy logic, which will
automatically switch occupancy levels from Occupied to Stand-By and
Unoccupied as required by local activity being present or not. This
advanced occupancy functionality provides advantageous energy savings
during occupied hours without sacrificing occupant comfort. All
thermostats can be ordered with or without a factory installed PIR
cover.
Signed-off-by: Jon Trulson <jtrulson@ics.com>